Go Mdbus MCP
Modbus TCP MCP server in Go with stdio/SSE/streamable transports, resilient reconnects, and typed read/write tools for holding registers and coils.
Ask AI about Go Mdbus MCP
Powered by Claude · Grounded in docs
I know everything about Go Mdbus MCP. Ask me about installation, configuration, usage, or troubleshooting.
0/500
Reviews
Documentation
Go Modbus MCP Server
A lightweight, high-performance Model Context Protocol (MCP) server for communicating with Modbus TCP devices. It exposes physical PLC hardware logic, registers, and coils to Large Language Models natively via MCP tools.
Key Features
- Official SDK: Built securely on top of the official
github.com/modelcontextprotocol/go-sdk. - Multiple Transports: Fully supports
stdio, Server-Sent Events (sse), and the new Streamable HTTP (streamable) MCP protocols. - Pluggable Drivers: Supports
goburrowandsimonvetterdrivers via--modbus-driver. - RTU + TCP Modes: Supports both
tcpandrtubus modes via--modbus-mode. - Session-Safe Streamable HTTP: Streamable transport runs in stateless JSON mode to avoid stale session issues (
session not found) across reconnects. - Resilient Connections: Thread-safe Modbus dialer reconnects safely for each operation and recovers cleanly from idle timeout disconnects.
- Write Safety Guard: Write tools are disabled by default and require explicit enablement via environment policy.
- Auto-Recovery Controls: Configurable retry/backoff and circuit protection for transient network failures.
- Strongly Typed: Input parsing schemas are automatically generated leveraging JSON Schema struct extraction.
- Container Ready: Includes health checks (
/healthon port 8080) and a multi-stage Docker build process.
Available Tools
The server exposes the following MCP Tools to your LLM:
read-holding-registers: Read an array ofuint16values from a specified address.read-coils: Read an array ofbooleanflags from a specified digital input/output address.read-input-registers: Read Modbus input registers.read-discrete-inputs: Read Modbus discrete inputs.read-holding-registers-typed: Read and decode typed holding-register values (uint16,int16,uint32,int32,float32,string) with optional byte/word order and scale/offset.write-holding-registers: Write an array ofuint16values sequentially starting at a specified address.write-holding-registers-typed: Encode and write typed holding-register values (uint16,int16,uint32,int32,float32,string) with optional byte/word order and scale/offset.write-coils: Write an array ofbooleanflags sequentially starting at a specified address.get-modbus-client-status: Inspect retry counters, failures, and circuit state.list-tags: List configured semantic tag definitions.read-tag: Read by semantic tag name.write-tag: Write by semantic tag name (subject to write policy), with raw arrays or typed values (numeric_value,string_value,bool_value).
Quick Start
Build & Run Locally
Ensure you have Go 1.25+ installed.
Toolchain policy: this repository is pinned to Go 1.25 across local development, CI, and Docker builds.
go build -o modbus-server .
# Connect to a default simulator (192.168.1.22:5002) using Streamable HTTP on port 8080
./modbus-server
# Load settings from YAML/JSON config file
./modbus-server --config ./server-config.yaml
# Or pass tag mapping CSV directly
./modbus-server --tag-map-csv ./tag-map.csv
# Run fully in-memory (no PLC required)
./modbus-server --mock-mode --config ./server-config.yaml
# Connect to a specific PLC IP and Port using STDIO (Best for Claude Desktop / Cursor)
./modbus-server --modbus-ip 10.0.0.50 --modbus-port 502 --transport stdio
# Use simonvetter driver over TCP
./modbus-server --modbus-driver simonvetter --modbus-mode tcp --modbus-ip 10.0.0.50 --modbus-port 502
# Use simonvetter driver over RTU serial
./modbus-server --modbus-driver simonvetter --modbus-mode rtu --serial-port /dev/ttyUSB0 --baud-rate 9600 --data-bits 8 --parity N --stop-bits 1
# Run using standard Server-Sent Events (SSE)
./modbus-server --transport sse
# Enable writes explicitly (disabled by default)
MODBUS_WRITES_ENABLED=true ./modbus-server
# Tune retries and circuit behavior
./modbus-server --modbus-retry-attempts 3 --modbus-retry-backoff 150ms --modbus-circuit-trip-after 3 --modbus-circuit-open-for 2s
Write policy environment variables:
MODBUS_WRITES_ENABLED:true|false(defaultfalse)MODBUS_WRITE_ALLOWLIST: optional global address allowlist, e.g.0-50,100,120-130MODBUS_WRITE_ALLOWLIST_HOLDING: optional allowlist override for holding-register writesMODBUS_WRITE_ALLOWLIST_COILS: optional allowlist override for coil writes
You can also set write policy, retry settings, and tag-map CSV in config file (YAML/JSON). CLI flags override config file values.
Recommended: keep semantic tag definitions in CSV (tag_map_csv) rather than embedding tags directly in config.
Example server-config.yaml:
modbus_ip: 192.168.1.22
modbus_port: 5002
modbus_driver: goburrow
modbus_mode: tcp
serial_port: /dev/ttyUSB0
baud_rate: 9600
data_bits: 8
parity: N
stop_bits: 1
transport: streamable
tag_map_csv: ./tag-map.csv
modbus_timeout: 10s
modbus_idle_timeout: 2s
modbus_retry_attempts: 3
modbus_retry_backoff: 150ms
modbus_retry_on_write: false
modbus_circuit_trip_after: 3
modbus_circuit_open_for: 2s
mock_mode: false
mock_registers: 1024
mock_coils: 1024
write_policy:
writes_enabled: false
write_allowlist: "0-9"
holding_write_allowlist: "0-20"
coil_write_allowlist: "0-5"
Tag CSV columns:
- Required:
name,kind,address - Optional:
quantity,slave_id,access,data_type,byte_order,word_order,scale,offset,description
Supported data_type for holding-register tags:
uint16,int16,uint32,int32,float32,string
Supported data_type for coil tags:
bool
Typed write-tag inputs:
numeric_valuefor numeric holding tagsstring_valuefor string holding tagsbool_valuefor single-coil tags (quantity=1)
Docker Usage
# Build the image
docker build -t go-mdbus-mcp .
# Run the server (exposes port 8080)
docker run -p 8080:8080 go-mdbus-mcp ./modbus-server --modbus-ip 10.0.0.50 --modbus-port 502 --transport sse
Integrating with Claude Desktop
To use this server natively in Claude Desktop, add the following to your claude_desktop_config.json:
{
"mcpServers": {
"modbus": {
"command": "/path/to/your/compiled/modbus-server",
"args": [
"--transport", "stdio",
"--modbus-ip", "192.168.1.22",
"--modbus-port", "502"
]
}
}
}
Contributing & Testing
Detailed usage and OpenCode validation steps are documented in HOW_TO_USE.md.
Historical validation run notes are archived in docs/archive/TEST_DOCUMENT.md.
Security deployment guidance is documented in SECURITY.md.
Configuration and precedence reference is documented in CONFIG_REFERENCE.md.
Tag CSV schema and typing reference is documented in TAG_CSV_REFERENCE.md.
Architecture overview is documented in ARCHITECTURE.md.
Detailed review notes and remediation status are documented in CODE_REVIEW.md.
Standard Go toolchains are used. The heavy lifting is done via the modbus folder.
go test ./...
make bench