siglent-spd-mcp
MCP server for Siglent SPD Series Power Supplies (SPD3303X, SPD3303X-E, SPD1168X, etc.).
Exposes voltage/current control, measurement, monitoring, timer, and system configuration as Model Context Protocol tools over SCPI/TCP.
Installation
pip install siglent-spd-mcp
Configuration
The server connects to the power supply via TCP/SCPI. Set the host and port with environment variables:
| Variable | Default | Description |
|---|---|---|
SPD_HOST | (required) | IP address of the power supply |
SPD_PORT | 5025 | SCPI TCP port |
Permissions (default: readonly)
All channels default to read-only. Set to readwrite to allow control:
| Variable | Values | Description |
|---|---|---|
CH1_PERM | readonly / readwrite | Channel 1 write access |
CH2_PERM | readonly / readwrite | Channel 2 write access |
CH3_PERM | readonly / readwrite | Channel 3 write access |
NETWORK_PERM | readonly / readwrite | Network config write access |
MEMORY_PERM | readonly / readwrite | Save/recall write access |
Safety limits (optional)
Set per-channel voltage and current limits to prevent accidental damage:
| Variable | Example | Description |
|---|---|---|
CH1_MAX_VOLTAGE | 5.0 | Max voltage for CH1 (V) |
CH1_MAX_CURRENT | 1.0 | Max current for CH1 (A) |
CH2_MAX_VOLTAGE | 32.0 | Max voltage for CH2 (V) |
CH2_MAX_CURRENT | 3.2 | Max current for CH2 (A) |
Usage
Claude Desktop / Claude Code
Add to your MCP client configuration:
{
"mcpServers": {
"siglent-spd": {
"command": "siglent-spd-mcp",
"env": {
"SPD_HOST": "192.168.1.100",
"CH1_PERM": "readwrite",
"CH1_MAX_VOLTAGE": "5.0",
"CH1_MAX_CURRENT": "1.0"
}
}
}
}
Direct execution
# Via entry point
siglent-spd-mcp
# Via module
python -m siglent_spd_mcp
Tools
Identification
identify- Query instrument ID (manufacturer, model, serial, firmware)
Measurement
measure_voltage- Measure actual output voltagemeasure_current- Measure actual output currentmeasure_power- Measure actual output powermeasure_all- Measure voltage, current, and power in one call
Control
set_voltage- Set voltage setpointget_voltage- Query voltage setpointset_current- Set current limitget_current- Query current setpointset_output- Turn channel output on/offset_tracking_mode- Set tracking mode (independent/series/parallel)
Monitoring
monitor- Measure for a fixed duration, return time-series datastart_monitor- Start continuous background measurementstop_monitor- Stop background monitor and return collected dataget_monitor_data- Peek at data from a running monitor
Timer
set_timer- Configure timer group parametersget_timer- Query timer group parametersset_timer_state- Enable/disable timer function
System
get_system_status- Query decoded system status flagsget_error- Query error codeget_version- Query software versionget_safety_config- Show configured permissions and safety limits
Save/Recall
save_state- Save instrument state to nonvolatile memoryrecall_state- Recall instrument state (with safety limit checks)
Network
set_ip/get_ip- Static IP addressset_mask/get_mask- Subnet maskset_gateway/get_gateway- Gateway addressset_dhcp/get_dhcp- DHCP enable/disable
Display
set_waveform_display- Toggle waveform display per channel